Examples are valid for:
TMflow Software version: 1.76.6300 or above.
TM Robot Hardware version: HW 3.2 or above
Other specific requirements: None
Note that older or latest software and hardware versions may have different results.
Hardware Installation Guide #
Note :
- For Profinet card , please contact our sales team for purchasing purpose
- The picture in this document is using Control Box for Hardware 3.2 , please note that different control box version might slightly has different installation position due to control box version
Hardware Preparation : #
Hardware Installation Procedure : #
Step 1 : Remove the top cover of control box
Step 2 : Remove the “flexible flat cable”
Step 3 : Find the mini- PCIE slot
Step 4 : Install the PROFINET mini-PCIE board and communication cable (please check your control box version and refer to the picture)
Step 5 : Fix the board by screw
Step 6 : Remove the barrier plate
Step 7 : Install the PROFINET communication Module
Step 8 : Plug-in the communication cable and assemble back the top cover of control box
SF (System Fault) = Hardware or software error
BF (Bus Fault) = Bus error (for CPUs with DP interface only)
Software Installation Guide #
NOTE :
- If the pre-install HMI (factory image) is HMI v1.80 and above, users can skip step 1-4 below and start from step 5 (FW only)
- If the pre-install HMI (factory image) is lower than TMflow 1.76, please follow step 1-5 (Image + FW)
- If the pre-install HMI (factory image) is TMflow 1.76 or above but the PROFINET device is not pre-install, please execute the Step 5 below “Update/Check FW & Setting” .
- For FW data, please ask your FAE to provide it and note that a maintenance dongle is also needed.
- If you want to upgrade the HMI from version 1.76 to version 1.80, please remove the PROFINET mini-PCIE board before the upgrade.
Software Installation – Step Overview #
IMAGE :
- Install cifX Device Driver (cifX Device Driver Setup.exe)
- Install SYCON.net (SYCONnet netX setup.exe)
- Modify Windows Registry Setting (CIFX_Edit_InstallDir.reg)
- Duplicate Driver Folder (CIFX_Copy_Files.bat)
FIRMWARE :
5. Update/Check FW & Setting
– CifxSetup.exe
– CifxTest.exe
STEP 1. Install cifX Device Driver
STEP 2. Install SYCON.net
STEP 3. Modify Windows Registry Setting
- Execute CIFX Edit InstallDir.reg
- [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\services\CifXDrv]
STEP 4. Duplicate Driver Folder
- Execute CIFX Copy Files.bat
STEP 5. FW Update and Boot Up Setting
- CifxSetup.exe
- CifxTest.exe
Note : Please make sure to burn FW into Profinet Hardware first to enable driver and configure workable
5-1. Update FW & Setting – CifxSetup.exe #
Follow the steps in the picture based on the description in the picture.
5-2. Check FW & Setting – CifxSetup.exe #
Follow the instructions based on the picture above